Southbound Drivers
Device Drivers
Design docs, test reports, and optimization notes for edgeCore southbound drivers — Modbus, BACnet, OPC UA, S7, EtherNet/IP, Omron FINS, SNMP, IEC 104, DL/T645, Mitsubishi MC, Profinet IO, KNXnet/IP, and more.
Driver Support Matrix
| Protocol | Registry Key | Status | Read | Write | Scan / Discover | ConnectionManager | Unit Tests (-short cov) |
|---|---|---|---|---|---|---|---|
| Modbus TCP/RTU | modbus-tcp, modbus-rtu, modbus-rtu-over-tcp |
Production | Yes | Yes | — | Yes | 65.9% |
| BACnet IP | bacnet-ip |
Production | Yes | Yes | Scan + ScanObjects | Partial | 66.1% |
| OPC UA Client | opc-ua |
Production | Yes | Yes | Scan + ScanObjects | Yes | 47.9% |
| Siemens S7 | s7 |
Production | Yes | Yes | — | Yes | 61.3% |
| EtherNet/IP | ethernet-ip |
Production | Yes | Yes | — | Yes | 62.2% |
| Omron FINS | omron-fins |
Production | Yes | Yes | — | Yes | 43.3% |
| SNMP v2c/v3 | snmp |
Production | Yes | Yes | ScanObjects | Yes | 63.7% |
| IEC 60870-5-104 | iec60870-5-104 |
M1 delivered | Yes | Yes (single command) | — | Yes | 60.2% |
| DL/T645-2007 | dlt645 |
Production | Yes | Yes | — | Yes | 76.5% ✅ |
| Mitsubishi SLMP | mitsubishi-slmp |
Production | Yes | Yes | — | Yes | 70.7% ✅ |
| Profinet IO | profinet-io |
Production | Yes | Yes | — | Yes | 55.9% |
| KNXnet/IP | knxnet-ip |
Production Ready | Yes | Yes | Gateway Discovery | Yes | 77.2% ✅ |
| EtherCAT | ethercat |
M1 Delivered | PDO + SDO | PDO + SDO | Yes | Yes | 87.8% ✅ |
ConnectionManager (shared component): 87.4% · Main driver package 22/22 PASS (2026-07-12)
Key Configuration Parameters
| Driver | Main Config Keys |
|---|---|
| Modbus | ip, port, slaveId, timeout, connection type (TCP/RTU/RTU-over-TCP) |
| BACnet | ip, port, deviceId, broadcast interface, object instance |
| OPC UA | endpoint, security policy/mode, credentials, subscription interval |
| S7 | ip, port, rack, slot, PLC model (200Smart/1200/1500/300/400) |
| EtherNet/IP | ip, port, slot, tag path, connection type |
| Omron FINS | plcIP/ip, plcPort/port, timeout, src/dst node addresses, TCP/UDP mode |
| Mitsubishi MC | ip, port, frame_type, network_no, station_no, timeout |
| Profinet IO | local_interface, timeout, simulation; device ip, port, slot, subslot |
| KNXnet/IP | ip, port, mode (TCP/UDP), discovery, discovery_timeout, discovery_multicast |
| SNMP | snmpVersion, targetIP, community (v2c), USM auth/priv (v3), maxBulkSize |
| DLT645 | connectionType (serial/tcp), port, ip, baudRate, timeout, meter address + DI |
| IEC 104 | ip, port, commonAddress, T0–T3 timers, general call interval |
Connection Management (2026-06)
Shared ConnectionManager (internal/driver/connection_manager.go):
- State machine:
Disconnected → Connecting → Connected → Retrying → Dead - Exponential backoff with jitter and cooldown (max 1 hour)
- Collection health: successful read = healthy; no separate heartbeat
- Low-frequency probe when scan interval exceeds 3× threshold
Supported: S7, Modbus, EtherNet/IP, OPC UA, FINS, SNMP, DL/T645, Profinet IO, KNXnet/IP
Test Coverage
Full report: Southbound Driver Test Report
CGO_ENABLED=0 go test ./internal/driver/modbus ./internal/driver/bacnet ... -count=1 -cover
Last run (2026-07-04): all 21 main driver packages PASS under -short; extended coverage_test.go across drivers. Integration/manual tags documented in the test report.